| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
| AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 125.0 AC |
| CASE MATERIAL | PLASTIC |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 2.812 INCHES NOMINAL FIRST MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.812 INCHES NOMINAL FIRST MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 90.435 CUBIC INCHES |
| ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| FREQUENCY IN HERTZ | 60.0 NOMINAL |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 3.810 INCHES MAXIMUM |
| OVERALL LENGTH | 6.230 INCHES MAXIMUM |
| OVERALL WIDTH | 3.810 INCHES MAXIMUM |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
| MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SECOND MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE FIRST MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 11 SCREW ALL FUNCTIONS |
| THREAD CLASS | 2B SECOND MOUNTING FACILITY |
| THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
| TIME DELAY | 0.10 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 1.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.156 INCHES NOMINAL FIRST MOUNTING FACILITY |