| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 33.758 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| FREQUENCY IN HERTZ | 60.0 NOMINAL |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC AND 100.0 AMPERES DC MOTOR LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC AND 100.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC AND 100.0 AMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| OVERALL HEIGHT | 2.822 INCHES MAXIMUM |
| OVERALL LENGTH | 3.625 INCHES MAXIMUM |
| OVERALL WIDTH | 3.300 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 200.0 MILLIAMPERES AC SINGLE WINDING |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 6 THREADED STUD ALL FUNCTIONS |
| TERMINAL TYPE AND QUANTITY | 2 SCREW ENERGIZING ELEMENT |
| TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |