5999-01-382-6166 PLATE,ELECTRICAL SHIELD Index 5998-01-382-6168 CIRCUIT CARD ASSEMBLY

National Stock Number:
5945-01-382-6167

Federal Supply Class:
5945

National Item Identification Number:
013826167

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
M39016/29-055L81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39016/29-055M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39016/29-055P81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-3901681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39016/2981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-3901681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39016/2981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
COIL QUANTITY2
CRITICALITY CODE JUSTIFICATIONFEAT
ENVIRONMENTAL PROTECTIONHERMETIC
FREQUENCY IN HERTZ60.0 NOMINAL AND 400.0 NOMINAL
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE500.0 MILLIAMPERES AC RESISTIVE LOAD
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP5.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS
OVERALL DIAMETER0.275 INCHES MINIMUM AND 0.335 INCHES MAXIMUM
OVERALL LENGTH0.280 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY1 TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED
PRECIOUS MATERIAL AND LOCATIONTERMINAL SURFACES GOLD
PRECIOUS MATERIALGOLD
SPECIAL FEATURESFAILURE RATE 1.0 PERCENT PER 10.000 CYCLES
WINDING DC RESISTANCE RATING61.0 OHMS NOMINAL FIRST WINDING
WINDING QUANTITY2
SPECIFICATION/STANDARD DATAMIL-R-81349-39016/29 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY9 WIRE LEAD ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.002 SECONDS MAXIMUM FIXED OPERATE TIME


Click here to Register for Free 30-day Trial