| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 38.100 MILLIMETERS NOMINAL SECOND MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 76.200 MILLIMETERS NOMINAL FIRST MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 27.559 MILLIMETERS NOMINAL SECOND MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 31.750 MILLIMETERS NOMINAL FIRST MOUNTING FACILITY |
| ENVIRONMENTAL PROTECTION | HERMETIC AND HEAT RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| FREQUENCY IN HERTZ | 54.7 MINIMUM OR 65.5 MAXIMUM |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| OVERALL HEIGHT | 91.546 MILLIMETERS MAXIMUM |
| OVERALL LENGTH | 92.964 MILLIMETERS MAXIMUM |
| OVERALL WIDTH | 55.372 MILLIMETERS MAXIMUM |
| MATERIAL | STEEL CORROSION RESISTING CASE |
| MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 ELECTRICAL PLUG CONNECTOR SECOND MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) FIRST MOUNTING FACILITY |
| SPECIAL FEATURES | MANUF.NAME, POWER MONITOR;USED TO SENSE LINE VOLTAGE,FREQUENCY AND PHASE SEQUENCE OF THREE PHASE Y POWER LINES UNDER VOLTAGE PICKUP LINE TO NEUTRAL 105 VRMS + - 2 PERCENT, OVERVOLTAGE DROP OUT LINE TO NEUTRAL 135 VRMS + - 2PERCENT |
| UNTHREADED MOUNTING HOLE DIAMETER | 5.130 MILLIMETERS MINIMUM AND 5.384 MILLIMETERS MAXIMUM FIRST MOUNTING FACILITY |
| TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG ALL FUNCTIONS |
| TIME DELAY | 2.00 SECONDS MAXIMUM FIXED RELEASE TIME |
| TIME DELAY | 4.00 SECONDS MAXIMUM FIXED OPERATE TIME |