| NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND |
| 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES DC RESISTIVE LOAD |
| 12.0 AMPERES DC INDUCTIVE LOAD |
| 5.0 AMPERES DC LAMP LOAD |
| 10.0 AMPERES DC MOTOR LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 260.0 OHMS MINIMUM SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 9 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 1.718 INCHES MAXIMUM |
| OVERALL WIDTH | 1.025 INCHES MAXIMUM |
| OVERALL HEIGHT | 1.010 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| SPECIAL FEATURES | FAILURE RATE OF 1.0 PERCENT PER 10,000 CYCLES |
| TEST DATA DOCUMENT | 81349-MIL-PRF-83536 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-83536/32-003 GOVERNMENT SPECIFICATION |
| SPEC/STD CONTROLLING DATA | |
| NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-83536/32 |
| MANUFACTURERS CODE | 81349 |
| DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M83536/32-003 |