5310-00-089-9619 NUT,SELF-LOCKING,HEXAGON Index 5905-00-089-9621 RESISTOR,VARIABLE,WIRE WOUND,NON

National Stock Number:
5950-00-089-9620

Federal Supply Class:
5950

National Item Identification Number:
000899620

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
ABA20180103VEECO INSTRUMENTS INC LAMBDA DIV


Techincal Specification:
TERMINAL TYPE AND QUANTITY8 WIRE LEAD
WINDING OPERATING VOLTAGE35.60 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY
27.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
105.00 AC VOLTS NOMINAL AND
132.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
870.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
FREQUENCY RATING55.0 HERTZ MINIMUM AND
480.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEPARTIALLY INCLOSED, HALF SHELL
BODY LENGTH3.094 INCHES NOMINAL
BODY HEIGHT2.037 INCHES NOMINAL
BODY WIDTH3.625 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
MAXIMUM OPERATING TEMP80.0 DEG CELSIUS


Click here to Register for Free 30-day Trial