5950-00-903-1542 TRANSFORMER,POWER Index 5950-00-903-1544 TRANSFORMER,POWER

National Stock Number:
5950-00-903-1543

Federal Supply Class:
5950

National Item Identification Number:
009031543

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
0084915364B AND K TANK GAUGE CO
0084915634MAGNETIKA INC
VM552650508MAGNETIC COMPONENTS INC
27776570210HONEYWELL INTERNATIONAL INC.
27776572599ALLIEDSIGNAL INC DBA ALLIED-SIGNAL AEROSPACE CO
1480472964ROBERT M. HADLEY COMPANY, INC.


Techincal Specification:
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.960 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BODY HEIGHT1.620 INCHES MINIMUM AND 1.750 INCHES MAXIMUM
BODY LENGTH1.250 INCHES MINIMUM AND 1.310 INCHES MAXIMUM
BODY WIDTH1.250 INCHES MINIMUM AND 1.310 INCHES MAXIMUM
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM OPERATING TEMP125.0 DEG CELSIUS
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
OVERALL HEIGHT2.190 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT1.50 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT4.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT4.5 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE27.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE9.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY9 PIN
THREAD QUANTITY PER INCH32 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP


Click here to Register for Free 30-day Trial