5895-00-945-0651 CONTROL,FREQUENCY SELECTOR Index 5950-00-945-0653 TRANSFORMER,RADIO FREQUENCY

National Stock Number:
5950-00-945-0652

Federal Supply Class:
5950

National Item Identification Number:
009450652

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
172061-00081413BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
73C828-00304660AIL SYSTEMS INC SUB OF EATON CORP
73C828-00372964ROBERT M. HADLEY COMPANY, INC.
73C828-00390095INRCORE, LLC


Techincal Specification:
BODY LENGTH3.859 INCHES MINIMUM AND 3.891 INCHES MAXIMUM
BODY WIDTH2.172 INCHES MINIMUM AND 2.204 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.109 INCHES MINIMUM AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SECOND CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.109 INCHES MINIMUM AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY THIRD CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.552 INCHES MINIMUM AND 1.572 INCHES MAXIMUM SINGLE MOUNTING FACILITY FOURTH CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY FOURTH CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.672 INCHES MINIMUM AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY THIRD CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.672 INCHES MINIMUM AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY SECOND CENTER GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.109 INCHES MINIMUM AND 1.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY FIRST CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT
OVERALL HEIGHT1.859 INCHES MINIMUM AND 1.891 INCHES MAXIMUM
MAXIMUM OPERATING TEMP170.0 CELSIUS
MOUNTING FACILITY QUANTITY2 FIRST GROUP
MOUNTING FACILITY QUANTITY4 FOURTH GROUP
MOUNTING FACILITY QUANTITY4 SECOND GROUP
MOUNTING FACILITY QUANTITY4 THIRD GROUP
MOUNTING METHODTHREADED HOLE(S) ALL GROUPINGS
NOMINAL THREAD SIZE0.112 INCHES SECOND GROUP
NOMINAL THREAD SIZE0.112 INCHES THIRD GROUP
NOMINAL THREAD SIZE0.138 INCHES FIRST GROUP
NOMINAL THREAD SIZE0.164 INCHES FOURTH GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESTWO PRIMARY WINDINGS; SIX SECONDARY WINDINGS
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 6 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT84.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING VOLTAGE346.50 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE40.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE41.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST PRIMARY
WINDING OPERATING VOLTAGE3.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING VOLTAGE65.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE8.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND PRIMARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING POWER RATING1.6 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY
WINDING POWER RATING1.8 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY
WINDING POWER RATING13.86 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY
WINDING POWER RATING5.46 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY
TERMINAL TYPE AND QUANTITY25 TURRET
TEST DATA DOCUMENT04660-73C828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) ALL GROUPINGS
TRANSFORMER WINDING CONNECTION TYPEWYE-DELTA