| DC RESISTANCE RATING IN OHMS | 0.012 SINGLE COMPONENT SINGLE WINDING |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.870 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 2.4 KILOHERTZ NOMINAL SINGLE COMPONENT |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS PROOF AND FUNGUS RESISTANT AND MOISTURE PROOF AND VIBRATION PROOF |
| INCLOSURE TYPE | FULLY INCLOSED |
| INDUCTANCE RATING | 27.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
| INDUCTANCE TYPE | FIXED |
| OVERALL HEIGHT | 0.503 INCHES MAXIMUM |
| OVERALL LENGTH | 1.190 INCHES NOMINAL |
| OVERALL WIDTH | 0.640 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 55.0 CELSIUS |
| MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL SINGLE GROUP |
| MOUNTING METHOD | BRACKET(S) AND UNTHREADED HOLE(S) SINGLE GROUP |
| RATING METHOD | ELECTRICAL AND WINDING TURNS SINGLE COMPONENT SINGLE WINDING |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING CONDUCTOR SIZE | 0.02010 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING |
| WINDING OPERATING CURRENT | 6.4 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING |
| WINDING QUANTITY | 1 SINGLE COMPONENT |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| TEST DATA DOCUMENT | 09966-C235A109 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| TURN QUANTITY | 11 SINGLE COMPONENT SINGLE WINDING |