5950-01-071-1757 TRANSFORMER,POWER Index 5999-01-071-1760 HOLDER,CONTACT

National Stock Number:
5950-01-071-1758

Federal Supply Class:
5950

National Item Identification Number:
010711758

Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
166747-113B150RAYTHEON COMPANY
166747-1149956RAYTHEON COMPANY
166747-1154X10RAYTHEON COMPANY
2904831-1110001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
498828-1100204TRANSCON TECHNOLOGIES, LLC
498828-113B150RAYTHEON COMPANY
498828-1149956RAYTHEON COMPANY
498828-1154X10RAYTHEON COMPANY


Techincal Specification:
COIL FORM TYPESOLID SINGLE COMPONENT
CORE CONSTRUCTIONS0LID SINGLE COMPONENT
FEATURES PROVIDEDTINNED WIRE LEADS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONMOISTURE RESISTANT AND SALT SPRAY RESISTANT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING0.042 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM OPERATING TEMP125.0 DEG CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUP
OVERALL LENGTH0.340 INCHES MAXIMUM
QUALITY FACTOR60 MINIMUM SINGLE COMPONENT SINGLE WINDING
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT1.9 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BODY OUTSIDE DIAMETER0.150 INCHES MAXIMUM