TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
401534907187HONEYWELL INTERNATIONAL INC.
403434407187HONEYWELL INTERNATIONAL INC.
WE303015634MAGNETIKA INC
WE303026543WEMS ELECTRONICS TRANSFORMER GROUP


Techincal Specification:
BODY WIDTH2.580 INCHES MINIMUM AND 2.680 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.428 INCHES MINIMUM AND 2.448 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.161 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
OVERALL HEIGHT1.665 INCHES MAXIMUM
OVERALL LENGTH3.700 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY31 WIRE LEAD
TRANSFORMER WINDING CONNECTION TYPEWYE-OPEN DELTA AND WYE-WYE
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 7 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT390.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS MINIMUM AND 201.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE77.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY