5950-01-090-8021 TRANSFORMER,POWER Index 6210-01-090-8023 FIXTURE,LIGHTING

National Stock Number:
5950-01-090-8022

Federal Supply Class:
5950

National Item Identification Number:
010908022

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
930-011-40024039VARO LLC
A1215505584AUTODYNE MANUFACTURING CO INC
PEI 906213483PRECISION ELECTRONICS, INC
SM-D-88781280063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP105.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODSLOT SINGLE GROUP
MOUNTING SLOT WIDTH0.250 INCHES NOMINAL SINGLE GROUP
OVERALL HEIGHT4.750 INCHES MAXIMUM
OVERALL LENGTH4.500 INCHES MAXIMUM
OVERALL WIDTH3.500 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY7 THREADED STUD
TRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT6.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY


Click here to Register for Free 30-day Trial