| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM AND 2.448 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT AND SALT SPRAY RESISTANT AND VIBRATION RESISTANT |
| INCLOSURE TYPE | FULLY INCLOSED |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| OVERALL HEIGHT | 2.700 INCHES MAXIMUM |
| OVERALL LENGTH | 3.500 INCHES MAXIMUM |
| OVERALL WIDTH | 1.875 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 100.0 CELSIUS |
| MAXIMUM TRANSFORMER POWER RATING | 25.0 WATTS SINGLE COMPONENT |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.151 INCHES NOMINAL SINGLE GROUP |
| MOUNTING METHOD | UNTHREADED HOLE(S) SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 2.8 AMPERES DC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| WINDING OPERATING CURRENT | 5.5 AMPERES DC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING VOLTAGE | 199.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 21.30 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| WINDING OPERATING VOLTAGE | 22.40 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| TERMINAL TYPE AND QUANTITY | 12 TURRET |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |