5950-01-117-6349 REACTOR Index 5950-01-117-6351 TRANSFORMER,POWER

National Stock Number:
5950-01-117-6350

Federal Supply Class:
5950

National Item Identification Number:
011176350

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1101055196SORA POWER INC.
L50400045836090LOCKHEED MARTIN LIBRASCOPE CORP


Techincal Specification:
BODY HEIGHT1.620 INCHES NOMINAL
BODY LENGTH3.500 INCHES NOMINAL
BODY WIDTH1.510 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
OVERALL HEIGHT1.510 INCHES NOMINAL
OVERALL LENGTH3.500 INCHES NOMINAL
OVERALL WIDTH2.700 INCHES NOMINAL
MAXIMUM TRANSFORMER POWER RATING60.0 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.180 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE(S) SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING VOLTAGE103.50 AC VOLTS MINIMUM AND 126.50 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE4.80 AC VOLTS MINIMUM AND 5.20 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING60.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY6 TAB, SOLDER LUG
TRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA