| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 13.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT AND FUNGUS RESISTANT AND CORROSION RESISTANT |
| INCLOSURE TYPE | OPEN |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| OVERALL HEIGHT | 8.750 INCHES NOMINAL |
| OVERALL LENGTH | 20.000 INCHES NOMINAL |
| OVERALL WIDTH | 8.500 INCHES NOMINAL |
| MAXIMUM TRANSFORMER POWER RATING | 4.2 KILOVOLT-AMPERE SINGLE COMPONENT |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.375 INCHES NOMINAL SINGLE GROUP |
| MOUNTING METHOD | UNTHREADED HOLE(S) SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 1.7 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING OPERATING VOLTAGE | 1490.00 AC VOLTS NOMINAL AND 1305.00 AC VOLTS NOMINAL AND 1120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING OPERATING VOLTAGE | 480.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| TERMINAL TYPE AND QUANTITY | 1 TERMINAL BLOCK W/SCREWS |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |