| PROPRIETARY CHARACTERISTICS | PACS |
| MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
| MOUNTING METHOD | TERMINAL SINGLE GROUP |
| OVERALL LENGTH | 1.265 INCHES MAXIMUM |
| OVERALL WIDTH | 0.750 INCHES MAXIMUM |
| RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING OPERATING CURRENT | 40.0 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING |
| WINDING OPERATING VOLTAGE | 31.82 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE WINDING |
| WINDING QUANTITY | 1 SINGLE COMPONENT |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| TEST DATA DOCUMENT | 07031-322A170 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| BODY HEIGHT | 1.265 INCHES MAXIMUM |
| DC RESISTANCE RATING IN OHMS | 0.003 SINGLE COMPONENT SINGLE WINDING |
| FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT AND MOISTURE RESISTANT AND FLAME RESISTANT AND FUNGUS RESISTANT |
| INCLOSURE TYPE | FULLY INCLOSED |
| INDUCTANCE RATING | 4.60 MICROHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING AND 6.85 MICROHENRIES MAXIMUM SINGLE COMPONENT SINGLE WINDING |