5950-01-369-9020 COIL,RADIO FREQUENCY Index 5955-01-369-9022 CRYSTAL UNIT,QUARTZ

National Stock Number:
5950-01-369-9021

Federal Supply Class:
5950

National Item Identification Number:
013699021

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
33913S657TRANSISTOR DEVICES INC DBA FERNWOOD MAGNETICS DIV DIV CIRCUITEK DIVISION
3493109004TRANSISTOR DEVICES INC


Techincal Specification:
BODY HEIGHT2.380 INCHES MAXIMUM
BODY LENGTH4.800 INCHES MAXIMUM
BODY WIDTH2.380 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.760 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.260 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS
DISTANCE BETWEEN MOUNTING FACILITY CENTERS4.260 INCHES NOMINAL FIRST MOUNTING FACILITY ALL CENTER GROUPINGS
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.760 INCHES NOMINAL SECOND MOUNTING FACILITY ALL CENTER GROUPINGS
FREQUENCY RATING10.0 KILOHERTZ MINIMUM AND 100.0 KILOHERTZ MAXIMUM THIRD COMPONENT
FREQUENCY RATING50.0 KILOHERTZ NOMINAL FIRST COMPONENT
FREQUENCY RATING50.0 KILOHERTZ NOMINAL SECOND COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE ALL COMPONENTS
MAXIMUM OPERATING TEMP70.0 CELSIUS
MOUNTING FACILITY QUANTITY4 ALL GROUPINGS
MOUNTING METHODTHREADED HOLE(S) ALL GROUPINGS
NOMINAL THREAD SIZE0.138 INCHES ALL GROUPINGS
SPECIAL FEATURES200:1CURRENT TRANSFORMER AND FLYBACK TRANSFORMER
RELIABILITY INDICATORNOT ESTABLISHED
SPECIFICATION/STANDARD DATA09004-34931 MANUFACTURERS SOURCE CONTROL
WINDING FUNCTION AND QUANTITY4 PRIMARY AND 2 CONTROL AND 8 SECONDARY ALL COMPONENTS
WINDING OPERATING CURRENT1.1 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT1.15 AMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING CURRENT3.3 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT2.15 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE26.00 AC VOLTS MINIMUM AND 35.00 AC VOLTS MAXIMUM SINGLE COMPONENT FIRST PRIMARY
WINDING OPERATING VOLTAGE26.00 AC VOLTS MINIMUM AND 35.00 AC VOLTS MAXIMUM SINGLE COMPONENT SECOND PRIMARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL FIRST COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SECOND COMPONENT
TERMINAL TYPE AND QUANTITY22 TURRET
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) ALL GROUPINGS


Click here to Register for Free 30-day Trial