| BODY HEIGHT | 0.165 INCHES MINIMUM AND 0.185 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 0.355 INCHES MINIMUM AND 0.370 INCHES MAXIMUM |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| CURRENT RATING PER CHARACTERISTIC | 5.60 MILLIAMPERES FORWARD CURRENT, NONREPETITIVE, MAXIMUM PEAK TOTAL VALUE ABSOLUTE |
| DESIGN FUNCTION AND QUANTITY | 2 AMPLIFIER, OPERATIONAL, LINEAR |
| FEATURES PROVIDED | ELECTROSTATIC SENSITIVE |
| INCLOSURE CONFIGURATION | CAN |
| OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 70.0 MILLIWATTS |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | OP AMP, DUAL, LOW OFFSET |
| SPECIAL FEATURES | ESD |
| VOLTAGE RATING AND TYPE PER CHARACTERISTIC | 20.0 VOLTS NOMINAL POWER SOURCE |
| STORAGE TEMP RANGE | -65.0/+150.0 DEG CELSIUS |
| TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD |
| TEST DATA DOCUMENT | 96906-MIL-STD-883 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |