| STYLE DESIGNATOR | TRANSITION-1 TO 4 CABLES |
| MAIN BODY INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
| 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| FIRST BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
| 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| SECOND BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
| 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| THIRD BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
| 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| FOURTH BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
| 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH | 1.940 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.770 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| MAIN BODY WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
| 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| FIRST BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
| 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| SECOND BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
| 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| THIRD BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
| 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| FOURTH BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
| 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 2.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
| 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
| 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| MATERIAL | RUBBER, NEOPRENE, RT-501, RAYCLAD TUBES INC |
| COLOR | BLACK |
| FLEXIBILITY | FLEXIBLE |
| TEMP RATING | 150.0 DEG CELSIUS |
| MINIMUM TENSILE STRENGTH | 1200 POUNDS PER SQUARE INCH |
| DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH/ |
| ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND |
| MILDEW RESISTANT |
| RELIABILITY INDICATOR | NOT ESTABLISHED |