STYLE DESIGNATOR | WAVEGUIDE TO COAXIAL |
CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND |
| 0.705 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.620 INCHES MINIMUM AND |
| 0.625 INCHES MAXIMUM |
WAVEGUIDE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND |
| 0.314 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND |
| 0.394 INCHES MAXIMUM |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
MATERIAL | COPPER ALLOY SINGLE FLANGE |
FLANGE QUANTITY | 1 |
FLANGE STYLE | COVER TYPE FIRST FLANGE |
FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM AND |
| 0.707 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM AND |
| 0.396 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM AND |
| 1.328 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM AND |
| 1.328 INCHES MAXIMUM FIRST FLANGE |
FLANGE DEPTH | 0.298 INCHES MINIMUM AND |
| 0.328 INCHES MAXIMUM FIRST FLANGE |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SINGLE FLANGE ALL CONNECTION FACILITIES |
FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM AND |
| 0.147 INCHES MAXIMUM SINGLE FLANGE ALL CONNECTION FACILITIES |
VOLTAGE STANDING WAVE RATIO | 1.50 |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |