5985-01-407-6677 ATTENUATOR,VARIABLE Index 5985-01-407-6679 DUMMY LOAD,ELECTRICAL

National Stock Number:
5985-01-407-6678

Federal Supply Class:
5985

National Item Identification Number:
014076678

Description:
SWITCH,RADIO FREQUENCY TRANSMISS

Detail:
An item specifically designed for mechanically or electronically positioning one or more radio frequency transmission line sections so as to couple it or them to other sections in a radio frequency transmission line system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).


Manufacturer Information:
233868-194987CUBIC DEFENSE APPLICATIONS, INC.
9120T-500-3311332GENERAL MICROWAVE CORPORATION


Techincal Specification:
ACTUATOR OPERATING METHODRELAY
BODY STYLERECTANGULAR
COAXIAL CONNECTOR SERIES DESIGNATIONSMA
CONNECTOR END DESIGNFEMALE
COUPLING POSITION QUANTITY3
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.850 INCHES MINIMUM AND 0.905 INCHES MAXIMUM SINGLE MOUNTING FACILITY PATTERN
FREQUENCY RATING12.4 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM SINGLE FREQUENCY VOLTAGE STANDING WAVE RATIO
FREQUENCY RATING12.4 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM SINGLE FREQUENCY CROSSTALK REFERENCE
FREQUENCY RATING12.4 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM SINGLE FREQUENCY INSERTION LOSS REFERENCE
FREQUENCY RATING12.4 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM SINGLE FREQUENCY OPERATING
INSERTION LOSS IN DECIBELS2.20 SINGLE
OPERATING TEMP RANGE-65.0 TO 125.0 CELSIUS
OVERALL HEIGHT1.730 INCHES NOMINAL
OVERALL LENGTH1.860 INCHES NOMINAL
OVERALL WIDTH0.380 INCHES NOMINAL
MINIMUM CROSSTALK RATING IN DECIBELS40.0 SINGLE
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S)
MOUNTING FACILITY PATTERNTWO POSITION IN-LINE SINGLE MOUNTING FACILITY PATTERN
POLE QUANTITY1
UNTHREADED MOUNTING HOLE DIAMETER0.990 INCHES MINIMUM AND 1.090 INCHES MAXIMUM
VOLTAGE STANDING WAVE RATIO2.00 SINGLE
SPECIFICATION/STANDARD DATA94987-233868 MANUFACTURERS SPECIFICATION CONTROL
SWITCH OPERATION SEQUENCEMAKES BEFORE BREAKS
SWITCH RETURN MECHANISM TYPEFAIL-SAFE
SWITCH TYPENONTRANSFER
TERMINAL TYPE AND QUANTITY3 RECEPTACLE, COAXIAL AND 3 WIRE LEAD
THROW QUANTITY2


Click here to Register for Free 30-day Trial