| AVERAGE LIFE MEASUREMENT | HOURS |
| AVERAGE LIFE RATING | 50000.0 |
| BASIC SHAPE STYLE | IRREGULAR |
| CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
| CONNECTION CONTACT TYPE AND QUANTITY | 3 RECEPTACLE, COAXIAL EXTERNAL AND 1 TERMINAL STUD EXTERNAL |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 23.5 MINIMUM SINGLE VOLTAGE AND 24.5 MAXIMUM SINGLE VOLTAGE |
| FEATURES PROVIDED | AUTOMATIC GAIN CONTROL |
| FREQUENCY PER CHANNEL | 2.9 GIGAHERTZ MINIMUM OPERATING CHANNEL AND 3.1 GIGAHERTZ MAXIMUM OPERATING CHANNEL |
| IMPEDANCE RATING PER CHANNEL | 50.000 OHMS OPERATING CHANNEL |
| INCLOSURE TYPE | OPEN |
| INSTALLATION DESIGN | MECHANICAL |
| MAXIMUM OPERATING ALTITUDE RATING | 15000.0 FEET |
| OPERATING TEMP RANGE | -40.0 TO 68.0 CELSIUS |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | RF AMPLIFIER MODULE |
| SPECIAL FEATURES | PARAS 2.1.5, 2.1.5.1 & 2.1.5.2 ARE MUCH DIFFERENT DUE TO ENGINEERING CHANGE ORDERS ON PWR OUTPUT, DYNAMIC RANGE AND COMPRESSION POINT SO REQUIRES NEW NSN: PRR IS 225PPS TO 305PPS WITH PULSE WIDTH OF 6.800 MILLISEC: ALSO ELECTRO STATIC DISCHARGE SENSITIVE |
| VARIATION FREQUENCY RATING IN DECIBELS | -1.0 AND 1.0 |
| STORAGE TEMP RANGE | -62.0 TO 71.0 CELSIUS |