| DUTY CYCLE | CONTINUOUS |
| AC VOLTAGE RATING | 110.0 VOLTS NOMINAL |
| ACTUATION METHOD | MAGNETIC |
| ACTUATOR VOLTAGE | 110.0 AC |
| AMBIENT TEMP | 50.0 DEG CELSIUS |
| CONTROL TYPE | LOCAL OR REMOTE |
| FUSE ACCOMMODATION QUANTITY | 2 |
| FUSE CURRENT RATING IN AMPS | 10.0 |
| FEATURES PROVIDED | REVERSIBLE AND ACCESSORY LOCATION EXTERNAL AND CIRCUIT PROTECTION FUSE |
| FREQUENCY IN HERTZ | 60.0 |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF |
| LOAD PROTECTION TYPE | OVERLOAD |
| INCLOSURE FEATURE | DRIPPROOF |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | CONTROLLER A.C. MAGNETIC PNLC (PROGRAMMABLE CONTROLLER) |
| PHASE | SINGLE |
| PROPRIETARY CHARACTERISTICS | PACS |
| MOUNTING CONFIGURATION | EIGHT 0.656DIA HOLES FOR 0.625DIA MOUNTING BOLTS |
| NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | NOT DESIGNED PER NEMA STD |
| OPERATING VOLTAGE CHARACTERISTIC | FULL |
| OVERALL HEIGHT | 28.120 INCHES NOMINAL |
| OVERALL LENGTH | 24.120 INCHES NOMINAL |
| OVERALL WIDTH | 11.280 INCHES NOMINAL |
| SPECIAL FEATURES | DISTRIBUTION STATEMENT C;SHOCKPROOF GRADE A CLASS 1 OF MIL-S-901;EXCEPTIONS TO MIL-C-2212 ARE PNLC INPUT ISOLATION 1000VDC,PNLC OUTPUT ISOLATION 1000VAC |
| SWITCH FUNCTIONAL POSITIONS | ON AND OFF AND EMERGENCY LOWER AND CLOSE AND RAISE AND EMERGENCY AND LOWER |