6525-01-428-1312 SCREEN,X-RAY INTENSIFYING Index 6525-01-428-1314 SCREEN,X-RAY INTENSIFYING

National Stock Number:
6130-01-428-1313

Federal Supply Class:
6130

National Item Identification Number:
014281313

Description:
POWER SUPPLY

Detail:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.


Manufacturer Information:
3113AS220230003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
3113AS2202-130003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
S3DHX-115A-400(22-32)15755SURE POWER, INC
S3DHX1-115A-40015755SURE POWER, INC


Techincal Specification:
INPUT VOLTAGE RATING27.0 DC VOLTS NOMINAL SINGLE OPERATING POWER RQMT
OUTPUT FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE POWER OUTPUT
OUTPUT VOLTAGE RATING115.0 AC VOLTS NOMINAL SINGLE POWER OUTPUT
OVERALL HEIGHT1.500 INCHES NOMINAL
OVERALL LENGTH1.375 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE+0.0 TO 50.0 CELSIUS
PART NAME ASSIGNED BY CONTROLLING AGENCYPOWER SUPPLY, MODULAR DC TO AC
SPECIAL FEATURESWET SLUG SILVER CASED TANTALUM CAPACITORS SHALL NOT BE USED
SPECIAL TEST FEATURESVOLTAGE RANGE: 27.0VDC,TRANSIENT PROTECTION: 80.0V,VOLTAGE: 115VAC RMS SINUSODIAL,FREQUENCY: 400HZ,POWER: 20VA MIN,HARMONIC DISTORTION: 2.5 PERCENT MAX,VOLTAGE ADJUSTMENT: 21 PERCENT MIN
SPECIFICATION/STANDARD DATA96906-MIL-STD-130 GOVERNMENT STANDARD AND 96906-MIL-STD-202 GOVERNMENT STANDARD AND 81349-MIL-E-5400 GOVERNMENT SPECIFICATION