6145-01-071-3471 WIRE,ELECTRICAL Index 6145-01-071-3476 WIRE,ELECTRICAL

National Stock Number:
6145-01-071-3473

Federal Supply Class:
6145

National Item Identification Number:
010713473

Description:
WIRE,ELECTRICAL

Detail:
A single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. It may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. refers to buld quantities only. For items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see WIRE,(as modified), Includes Litz wire and insulated/uninsulated armored, and ground wire. Excludes BRAID, WIRE; FUSE WIRE; RESISTANCE WIRE and MAGNET WIRE.


Manufacturer Information:
17-00024-95805973CHAMPLAIN CABLE CORP SUB OF HUBER AND SUHNER INC
6145PL08184149009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
75918-24-95812515NEXANS AEROSPACE USA LLC
M22759/18-24-9580U583SAE INTERNATIONAL
M22759/18-24-95881343SOCIETY OF AUTOMOTIVE ENGINEERS INC
M22759/18-24-95881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-W-22759/1881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
SAE AS22759/180U583SAE INTERNATIONAL
SAE AS22759/1881343SOCIETY OF AUTOMOTIVE ENGINEERS INC
SAE-AS22759/180U583SAE INTERNATIONAL


Techincal Specification:
COLORWHITE 1ST POSITION COVER SINGLE CONDUCTOR
CONDUCTOR FORMSTRANDED SINGLE CONDUCTOR
CROSS SECTION OUTSIDE DIAMETER0.036 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR SINGLE CONDUCTOR
ROUND CONDUCTOR SIZE24 AWG SINGLE CONDUCTOR
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR36 SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 SINGLE CONDUCTOR
SURFACE TREATMENTTIN CORE CONDUCTOR SINGLE CONDUCTOR
TEMP RATING150.0 CELSIUS
TRACER COLORGRAY/GREY SECOND TRACER SINGLE CONDUCTOR
TRACER COLORGREEN FIRST TRACER SINGLE CONDUCTOR


Click here to Register for Free 30-day Trial