6140-01-572-7678 BATTERY,STORAGE Index 6145-01-570-5236 CABLE,POWER,ELECTRI

National Stock Number:
6145-01-567-0005

Federal Supply Class:
6145

National Item Identification Number:
015670005

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
M27500-12ML5T081P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
M27500-12ML5T0881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
NEMA WC 275001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
NEMA-WC275001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA


Techincal Specification:
CONDUCTOR ARRANGEMENT AND QUANTITY5 SINGLES
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR QUANTITY5
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER FIRST POSITION SHIELD BRAID METALLIC CABLE
MATERIALPLASTIC CROSS-LINKED POLYALKENE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATERIALPLASTIC CROSS-LINKED POLYVINYLIDENE FLUORIDE SECOND POSITION JACKET ALL CONDUCTORS
MATERIALPLASTIC CROSS-LINKED POLYVINYLIDENE FLUORIDE SECOND POSITION JACKET CABLE
ROUND CONDUCTOR SIZE12 AWG ALL CONDUCTORS
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR28 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR37 ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE TREATMENT RESPONSE FIRST POSITION SHIELD BRAID METALLIC CABLE
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN FIRST POSITION SHIELD BRAID METALLIC CABLE
TEMP RATING150.0 CELSIUS