INSTALLATION DESIGN | PANEL |
INDICATOR TYPE | DIAL W/POINTER |
MEASUREMENT RANGE | 4.0 TO 20.0 MILLIAMPERES, DC SINGLE INDICATOR SINGLE RANGE |
ACCURACY IN PERCENT | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
SCALE GRADUATION TYPE | NONLINEAR SINGLE INDICATOR SINGLE RANGE |
POINTER COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
BACKGROUND COLOR | WHITE SINGLE INDICATOR SINGLE RANGE |
MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
MOVEMENT SUSPENSION METHOD | JEWEL PIVOT BASE |
CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1500.0 |
POWER SOURCE | EXTERNAL |
CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
OPERATING VOLTAGE RATING IN VOLTS | 28.0 DC NOMINAL |
STYLE DESIGNATOR | RECTANGULAR SEMI-FLUSH MTG |
METER BODY HEIGHT BEHIND MOUNTING FLANGE | 1.225 INCHES MAXIMUM |
METER BODY WIDTH BEHIND MOUNTING FLANGE | 5.450 INCHES MAXIMUM |
METER DEPTH BEHIND MOUNTING FLANGE | 5.770 INCHES MAXIMUM |
OVERALL HEIGHT | 1.530 INCHES MAXIMUM |
OVERALL LENGTH | 7.730 INCHES MAXIMUM |
OVERALL WIDTH | 6.700 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 4 SCREW AND |
| 4 UNTHREADED HOLE |
MOUNTING HOLE DIAMETER | 0.190 INCHES NOMINAL |
MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.043 INCHES MINIMUM AND |
| 6.057 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.718 INCHES MINIMUM AND |
| 0.732 INCHES MAXIMUM |
PANEL FOR WHICH DESIGNED | MAGNETIC OR |
| NONMAGNETIC |
CIRCUIT CONSTRUCTION TYPE | NONELECTRONIC |
MATERIAL | STEEL |
SURFACE TREATMENT | PAINT |
NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
ENVIRONMENTAL PROTECTION | HUMIDITY RESISTANT AND |
| SHOCK RESISTANT AND |
| VIBRATION RESISTANT |
FURNISHED ITEMS AND QUANTITY | NUT 8; WASHER 16 |
FEATURES PROVIDED | ELECTRICAL OVERLOAD PROTECTION AND |
| LUMINOUS SCALE MARKING AND |
| NONGLARE GLASS AND |
| SELF-ILLUMINATION FACILITY AND |
| ZERO ADJUSTER |
SPECIAL FEATURES | 0-20 FOOT TANK 5-162-2-F FUEL OIL SERVICE-REF |
SPECIAL TEST FEATURES | DRAWING IAW MIL-STD-100A; VIBRATION IAW MIL-STD-167; SHOCK IAW MIL-S-901; MARK IAW MIL-STD-130; SEAL IAW MIL-STD-108D |
CRITICALITY CODE JUSTIFICATION | FEAT |
SUPPLEMENTARY FEATURES | DAMPING FACTOR 10.0 MIN; RESPONSE TIME 2 SEC MAX; INSULATION RES 20 MEGOHS MIN; EDGEWISE MTG; RUGGEDIZED |
FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |