| INSTALLATION DESIGN | PANEL |
| PANEL FOR WHICH DESIGNED | MAGNETIC OR |
| NONMAGNETIC |
| INDICATOR TYPE | DIAL W/POINTER |
| SCALE MARKING | LOW LEVEL LEAK; HIGH LEVEL LEAK: 1; 2; 3; 5; 8; INTERLOCK OPEN OR TB LEAK LOCATION: 1; 2; 3; 5; 6; 8; 10; 15 |
| ACCURACY IN PERCENT | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR ALL RANGES |
| SCALE GRADUATION TYPE | NONLINEAR SINGLE INDICATOR ALL RANGES |
| POINTER COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| BACKGROUND COLOR | WHITE SINGLE INDICATOR ALL RANGES |
| MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
| MOVEMENT SUSPENSION METHOD | JEWEL PIVOT BASE |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
| SENSITIVITY RATING | 200.0 MICROAMPERES |
| DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 3000.0 |
| CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
| STYLE DESIGNATOR | RECTANGULAR FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.210 INCHES MAXIMUM |
| METER DEPTH BEHIND MOUNTING FLANGE | 1.600 INCHES MAXIMUM |
| OVERALL HEIGHT | 2.700 INCHES MAXIMUM |
| OVERALL LENGTH | 2.535 INCHES MAXIMUM |
| OVERALL WIDTH | 2.700 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
| MOUNTING STUD DIAMETER | 0.112 INCHES NOMINAL |
| MOUNTING STUD LENGTH | 0.500 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.880 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.880 INCHES NOMINAL |
| MATERIAL | STEEL |
| SURFACE TREATMENT | ENAMEL |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND |
| VIBRATION RESISTANT |
| SPECIAL MARKINGS | ARROW AND EXTENDED LINE AT 9 OF LOWER RANGE ABOVE SCALE |
| FEATURES PROVIDED | ZERO ADJUSTER |
| SPECIAL FEATURES | RUGGEDIZED |
| SPECIAL TEST FEATURES | CONFORMS TO MIL-M-10304/34 |
| SUPPLEMENTARY FEATURES | 150 MV MAX POWER CONSUMPTION |
| FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |