5975-01-257-9460 PANEL,ELECTRICAL-ELECTRONIC EQUI Index 5930-01-257-9462 SWITCH ASSEMBLY

National Stock Number:
6665-01-257-9461

Federal Supply Class:
6665

National Item Identification Number:
012579461

Description:
RADIACMETER

Detail:
AN ITEM SPECIFICALLY DESIGNED TO DETECT AND MEASURE RADIOACTIVE ENERGY; INDICATES DIRECTLY. IT MAY OR MAY NOT INCLUDE THE FUNCTION OF A RADIAC COMPUTER.


Manufacturer Information:
A-A-5074558536FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
A-A-5074598750SAN ANTONIO AIR LOGISTICS CENTER
PD87MMTRDF53698750SAN ANTONIO AIR LOGISTICS CENTER
PD87MMTRDF53698752WARNER ROBINS AIR LOGISTICS CENTER
A-A-5074598752WARNER ROBINS AIR LOGISTICS CENTER


Techincal Specification:
CARRYING CASENOT PROVIDED
DETECTING ELEMENT TYPEGEIGER TUBE
ENERGY DEPENDENCE RATING+40.0 TO 1200.0 KEV
FEATURES PROVIDEDINTERNAL BATTERY ACCOMMODATION
INDICATOR TYPEAUDIO AND VISUAL
OVERALL LENGTH4.300 INCHES NOMINAL
OVERALL WIDTH2.600 INCHES NOMINAL
MATERIALALUMINUM OR STEEL OR PLASTIC CASE
MOUNTING METHODCLIP
PORTABILITYPORTABLE
RADIATION RANGE PER HOUR+0.0 TO 9999.0 MILLIROENTGENS
RADIATION TYPE AND FUNCTIONGAMMA RAYS DETECTS AND X-RAYS DETECTS
SPECIAL FEATURESWEIGHT 7.3 OUNCES; A POCKET SIZED PERSONAL DOSIMETER DESIGNED TO BE WORN ON A POCKET OR BELT; ATTACHES TO POCKET OR BELT BY CLIP; CASE MADE OF HIGH IMPACT PLASTIC OR CORROSION RESISTING LIGHTWEIGHT METAL; HAS LOW BATTERY INDICATOR; 4 DIGIT LED DISPLAY; AUDIO ALARMS; ACCURACY +/- 15% OVER A RANGE OF 0.1 TO 1 R/HR REFERENCED TO CS-137
VOLTAGE IN VOLTS AND CURRENT TYPE9.0 DC
SUPPLEMENTARY FEATURESMANUFACTURERS NAME: PERSONAL ALARMING DOSIMETER